Abstract Time-temperature distribution
data was collected with water in a cylindrical container under different
types of electrical shielding. With no shielding or bottom shielding, the
temperature profiles in the radial direction were relatively uniform and the
axial temperatures decreased from the top to the bottom of the container. The
cold spot was along the central axis close to the bottom of the container.
When the top was shielded and microwave energy was allowed to enter from the
bottom, a uniform temperature distribution was observed throughout the
container. A flow pattern visualization technique for liquid products heated
in a microwave oven was developed. When the top of the container was
shielded, good mixing of the liquid was observed due to convection heating. Key Words: Microwave heating,
Electrical shielding, Flow profiles. |